UT267B

Shipping in
48h
  • Three-phase current clamp meter
  • LED backlit display
  • Measurement in AC up to 600V and 20A
  • Active, reactive and apparent power measurement
  • Power factor and phase angle measurement
  • Memory for data storage
  • Description
  • Specifications
  • Contents
  • Downloads
  • UNI-T
  • Three-phase clamp meter CAT II 600V/ CAT III 300V
  • LED backlit display
  • AC current measurement up to 20 A
  • Measurement of AC voltage up to 600 V
  • Frequency measurement 45Hz~65Hz
  • Active power measurement up to 12 kW
  • Reactive power measurement up to 12 kVAR
  • Apparent power measurement up to 12 kVA
  • Power factor measurement -1~+1
  • Phase angle measurement up to 360º
  • Storage of up to 99 data
  • Auto range
  • Blocking of securities
  • Communication via RS-232
  • Automatic shutdown
  • Low battery indicator
BrandUni-T
Measuring range AC current20A ±(1.5%+3)
Measuring range AC voltage600V ±(1.5%+3)
Frequency45Hz~65Hz
Active powerUp to 12kW ±(3%+3)
Reactive powerUp to 12kVAR ±(3%+3)
Apparent powerUp to 12kVA ±(3%+3)
Phase angleUp to 360º ±1°
Power factor-1~+1 ±0.03
Sum of current vectorsUp to 60A
Sampling rate0.5 samples/s
Number of phases3
Data storageUp to 99 values
CommunicationsRS-232
Display dimensions39.3mm x 26.5mm
Auto RangeYes, it has
Data blockingYes, it is available
Low battery indicatorYes, it has
Automatic shutdownYes available (15 min)
Clamp opening16mm
Power6 x batteries (LR6) 1.5V
Dimensions196 (H) x 92 (W) x 54 (D) mm
Weight550 g
SecurityCAT II 600V/ CAT III 300V CAT III [%VAR%]
  • Three-phase current clamp meter
  • Test clamps (x3)
  • Test leads (x4)
  • Batteries (x6)
  • User instructions

alt