Configurable combination detector, can be used with analog or conventional control panels. The detector composed of 2 separate and independent detection sections, an optical smoke detector and thermo-velocimetric detector of Category A1-58°, suffix R.

Highest accuracy in temperature detection and analysis of the captured smoke. Dynamic control and compensation of the sensitivity of the optical camera, automatic management of the maintenance threshold. Programmable functions: 3 sensitivity levels, excludable pre-alarm signaling, excludable optical detection section, formula association and management criterion for TFBASE-SIREN or TFRIP-SMART. The functional states of the detector can be used as operands in the formulas managed by the control panel.

CSR® Management: programming, remote management and control. Double line isolator. Base mounting

universal TFBASE01.

Available colors black or white.

EN 54-7:2018 - EN 54-5:2017 + A1:2018 - EN 54-17:2005.

Certificate of homologation: 0051-CPR-3133


  • TECNOFIRE
  • Configurable combined detector
  • Can be used with analog addressable or conventional control panels
  • Composed of 2 separate and independent sensing sections
Combined optical and thermovelocimetric smoke detector configurable TFDA-STR2
Detector configuration Addressable or Conventional
Programming Rotoswitch
Interrogation LED Excludable
Sensitivity 3 levels
Prealarm Excludable
Optical sensing section Excludable
Thermovelocimetric detector Category A1-58°
R Suffix
Management criteria Programmable
Address Software
Communication protocol FIRE-SPEED
Line separator Double insulator
Nominal voltage 24VDC
Operating voltage 18V…30VDC
Absorption 400µA @ 24V DC
Absorption in alarm 5mA @ 24V DC
Snooze alarm output 9,4V DC 3mA
Operating temperature -10°C...+55°C
Relative humidity (non-condensing) (without condensation) 10%...93%
Degree of protection IP22 relative humidity
(non-condensing)
Box ABS
Dimensions (D x H) 100 x 52mm
Weight 100g
Standards EN 54-5:2017 + A1:2018
EN 54-7:2018
EN 54-17:2005
Approval certificate 0051-CPR-3133 (D x H) 100 x 52mm
Year of CE marking 23
Benefit statement number053_TFDA-STR2
Certification body IMQ
  • Combined optical and thermovelocimetric detector with isolator

alt