Interface | 48 Ports SFP28 + 8 Ports QSFP28 + MGMT Port + Console Port + USB Port |
Port speed | 48x 10G/25G SFP28 + 8x 40G/100G QSFP28 |
Switching capacity | 4.0 Tbps |
Packet forwarding rate | 2000 Mpps |
Datacenter features | VXLAN routing and VXLAN bridging EVPN VXLAN VXLAN mapping IPv4 VXLAN over IPv4IPv6 VXLAN over IPv4 VXLAN over [%VAR%] IPv6 VXLAN over IPv6 IPv6 VXLAN over IPv6 M-LAG OpenFlow 1.3 RDMA, RoCEv2, PFC, and ECN |
Layer protocols 2 | IEEE802.3ae (10GBase), IEEE802.3ak, IEEE802.3an, IEEE802.3x, IEEE802.3ad (static link aggregation, LACP, M-LAG), IEEE802.1p, IEEE802.1Q, IEEE802.1D (STP), STP root protection, and BPDU protection IEEE802.1w (RSTP), IEEE802.1s (MSTP) IGMP Inspection v1/v2, MLD Inspection, Jumbo Frame (9 KB) IEEE 802.1ad (QinQ and selective QinQ), GVRP, three modes (access, trunk and hybrid), LLDP, static MAC address, MAC address filtering, MAC address limit, MAC address quantity limit |
Layer protocols 3 | Static routing, BGP4, OSPFv2, IS-IS, RIPv1, RIPv2, MBGP, LPM routing, policy-based routing (PBR), routing policy, ECMP, WCMP, VRRP, IGMP v1/v2/v3, PIM-SSM/SM/DM, MSDP and Any-RP, BFD for BGP/IS-IS/OSPF/static routing, manual tunneling, GRE tunneling |
MPLS | MPLS VPN |
QoS | IEEE priority mapping 802.1p, ToS and DSCP ACL traffic classifier and priority tagging (Mark/Remark) Various queue scheduling mechanisms, such as SP (PQ), WRR, DRR, SP (PQ)+WRR and SP (PQ)+DRR Flexible queue scheduling algorithms based on ports or queues Congestion avoidance mechanisms, such as WRED and queue discards Speed limiting based on input/output ports and CARs |
High availability | GR for RIP/OSPF/BGP, BFD, DLDP, VRRP, VRRP/dual-active load balancing, BFD for VRRP, REUP, RLDP, 1+1 power redundancy and fan redundancy, and hot-swappable line cards and power modules |
Security | Network Foundation Protection Policy (NFPP), CPU Protection Policy (CPP), defense against DDoS/DoS attacks, defense against ICMP attacks, rogue packet detection, data encryption, defense against source IP spoofing, defense against IP scanning attacks, RADIUS/TACACS, IPv4/v6 packet filtering via basic ACL, extended ACL, Port-based ACL or VLAN-based ACL, unencrypted text and MD5-based authentication for OSPF packets, RIPv2 and BGPv4, Telnet login from specific IP addresses, uRPF, broadcast packet suppression, DHCP monitoring, ARP spoofing defense (anti-ARP spoofing), ARP checking and hierarchical user management. |
Virtual Stacking | VSU technology that allows virtualizing 2 equipment in 1 |
Other protocols | DHCP client, DHCP relay, DHCP server, DNS client, UDP relay, ARP proxy, and syslog |
Protocol Management | SNMP v1/v2c/v3, Telnet, Console, MGMT, RMON, SSHv1/v2, FTP/TFTP, NTP, Syslog, SPAN/RSPAN/ERSPAN, Telemetry, ZTP, NETCONF, Python, fan and power alarm, temperature alarm and configuration rollback |
Power supply | Not included, 2 Slot supports redundancy 1+1
RG-PA550I-F (CA Input): Rated input voltage: 100 V AC to 240 V AC, 50 Hz/60 Hz Maximum input voltage: 90 V AC at 140 V AC, 180 V AC at 264 V AC, 47 Hz at 63 Hz Rated input current: 7,2 A to 3,5 A (100 V CA to 240 V CA) Power port type: C14
RG-PA550I-F (HVDC input): Rated input voltage: 240 V CC Maximum input voltage: 180 V CC a 310 V CC Rated current: 3,6 A Power port type: C14
RG-PHD550I-F (CA Input): Rated input voltage: 100 V AC to 240 V AC, 50 Hz/60 Hz Maximum input voltage: 90 V AC to 264 V AC, 47 Hz to 63 Hz Rated input current: 10 A Power port: C14
RG-PHD550I-F (HVDC input): Rated input voltage: 336 V CC Maximum input voltage: 160 V CC a 400 V CC Rated input current: 10 A Power port: C14
RG-PD800I-F (CC entry): Rated input voltage: –48 V CC Maximum input voltage: –36 V CC a –72 V CC Rated input current: 23 A Power port: three-pin |
Redundant fans | Including 4 units for 4 Slot, supports redundancy 2+2 |
Dimensions | 442 mm x 387 mm x 44 mm |
Consumption | Maximum : 300 W Habitual: 172 W Rest: 98 W |
Operating temperature | 0° C - 45° C |
Power | AC 100 V - 240 V |